Thesis
Development and validation of a gastroenterology probe capable of measuring the position of the squamo-columnar junction
- Creator
- Rights statement
- Awarding institution
- University of Strathclyde
- Date of award
- 2014
- Thesis identifier
- T13723
- Qualification Level
- Qualification Name
- Department, School or Faculty
- Abstract
- The squamo-columnar junction is an important landmark in the upper gastro-oesophageal anatomy, acid reflux occurring above this causes heartburn and may lead to oesophageal cancer if prolonged. Currently no medical device takes into account the position of the squamo-columnar junction despite its importance. The aim of this doctoral work is to develop and validate a device which is capable of monitoring the position of the squamocolumnar junction with respect to simultaneous acid reflux and pressure measurements. Using Hall effect sensors on a custom flexible circuit board, and a magnet attached to the squamo-columnar junction, a device was produced which when inserted into the oesophagus, measured the relative position of the squamocolumnar junction to manometry and pH-metry catheters. The accuracy of the measurement was at most 5 millimetres, often better; a better resolution than either the high resolution manometer or custom pH device. The device was validated in-vivo, demonstrating a capability of measuring significant movement of the squamo-columnar junction during transient lower oesophageal sphincter relaxations. The accuracy of the high resolution manometer was tested, which showed significant drift, capable of causing misdiagnosis. A correction algorithm was produced which corrected linear drift, removing time dependant drift leading to significantly more accurate pressure readings. Catheter based upper gastro-oesophageal measurements have the potential to cause transient lower oesophageal sphincter relaxations by triggering mechanoreceptors in the pharynx; therefore a non-catheter based squamo-columnar junction locator was designed and tested. Using a larger magnet and significantly more sensitive Hall effect sensors and custom analogue circuitry, the squamo-columnar junction could be detected. The distance between the oesophagus and the skin is estimated to be between 8 and 9 centimetres for a healthy, non-obese male adult, the detection range for the non-catheter based squamo-columnar junction locator was 10.4 centimetres. The devices developed for this doctoral work has improved the field of gastroenterology research.
- Resource Type
- DOI
- Date Created
- 2014
- Former identifier
- 1032420
Relations
Items
Thumbnail | Title | Date Uploaded | Visibility | Actions |
---|---|---|---|---|
|
PDF of thesis T13723 | 2021-07-02 | Public | Download |